Things Contractors Need To Know When Installing Zoning

1.) Does drywall need to be removed to install a damper system?

No. Our dampers have been designed specifically for applications where the ductwork has been buried and is not easily accessible. Check out our products page to find out more about our special application dampers such as the EZYFIT or INSERTA. All dampers come with a lifetime warranty. HVAC pros can register here for videos showing how easy Arzel dampers are to install.

2.) Not enough air coming through the registers?

Check the furnace manual on what the maximum static allowance is for the furnace. Then, adjust the system to run near the maximum static on the smallest zone without creating disturbing air noise for the homeowner. The maximum TSP could be as much as 0.8” to 1.0” W.C. and will have a much greater effect on the homeowner’s comfort. Keep in mind to never exceed the maximum static allowance for the furnace in order to prevent damages and ultimately warranties from being voided.

3.) Are pneumatic systems reliable?

Yes. Arzel systems operate pneumatically and have been providing comfort since 1983. We are so confident in their ability to provide reliable comfort we backed them with a lifetime warranty and our 100% comfort guarantee. Arzel is more than reliable, it’s very quiet. When installed properly, the systems perform near and less than 40 dB, which is typically the noise in a library environment.

4.) Can smart thermostats be used?

 Yes. Smart thermostats that allow for conventional 24vac outputs are compatible will all Arzel zoning panels, MPS, Airboss, HPP, Evergreen, Coolmizer. We know that our contractors and homeowners have their preferred thermostats and we wanted to make sure that Arzel would be compatible with what’s familiar.

5.) Do I need a bypass?

It depends. Bypass often isn’t needed but this will depend highly on the application. Bypass is usually applied incorrectly and oversized for the application. The design and layout of the HVAC system determines whether a bypass is required. There are many ways to control the static or airflow noise in the HVAC system. We are happy to discuss proper bypass application, call us at 800-611-8312.

Recent Posts
View All

Summer is here, and with that comes a rush of service calls; in that rush, as technicians, we often skip the basics of air conditioning performance, starting with proper airflow. Air conditioning requires proper airflow and proper airflow changes with static pressure. The Total External Static Pressure (TESP) corresponds to blower performance data charts. For […]

As an HVAC contractor, correctly sizing the furnace and air conditioner for your client’s home or business is essential. Accurate load calculations prevent the risks associated with oversized or undersized systems, such as increased energy costs, reduced efficiency, and premature equipment failure. Load calculations, or “Manual J” for residential and light commercial applications, consider factors […]

Intro: When evaluating a building for zoning, one of the most important steps is measuring the duct capacity, or how many Cubic Feet Per Minute (CFM) the duct can deliver. This post will discuss the importance of measuring the CFM capacity of a building’s ductwork and provide an overview of the process for calculating CFM […]

If you’re an HVAC contractor looking to design a custom HVAC system for a unique application, Arzel® zoning systems are an excellent choice. By taking advantage of the unique features and benefits Arzel® offers, you can design an HVAC system tailored to your customer’s specific needs. This blog post will look at the possibilities and […]